Operate a fire curtain and a smoke barrier in 3D. Trigger the alarm, press the emergency or escape button, cut the mains power and watch the curtain deploy, close the opening and, on irrigated models, start spraying. Use the buttons under the picture or click the buttons on the wall.
Fire Curtain and Smoke Barrier 3D Demo
What you can try
- Choose a fire curtain model: BACHFIRE E 120, TRIAFIRE E 120, MEGAFIRE EI60, MEGAFIRE EI120, SUPERFIRE EI 180 or SUPERFIRE EI 120.
- Trigger the automatic fire alarm, the emergency button or the escape button.
- Cut the mains power and see the curtain react on battery.
- On the SUPERFIRE models, watch the irrigation open after its 3 minute delay.
- Switch to the smoke barrier scene and compare 1.5, 2.5 and 3.5 m drops, or take the barrier away.
- Orbit and zoom the 3D view, and run it in real time, 8× or 20× speed.
How the curtain behaves in the demo
- Fire alarm: the fire starts behind the opening, the signal reaches the control panel and the curtain deploys at constant speed.
- Emergency button: the curtain deploys at once.
- Escape button: the curtain lifts so people can pass, then deploys again on its own after 30 seconds.
- Mains power lost: the battery holds the curtain retracted, and an alarm still deploys it.
- Irrigation: on the SUPERFIRE models the water opens 3 minutes after the alarm, once the curtain is down. SUPERFIRE EI 180 needs at least 3.8 l/min/m² at 1.4 bar and SUPERFIRE EI 120 at least 6.5 l/min/m² at 3.2 bar.
Limits of the demo
The demo is for illustration only. Colours, proportions and smoke movement are simplified, the deployment speed in the smoke barrier scene is an assumed value, and the 3D model is not a certified drawing or a test result. SUPERFIRE Z and TRIAFIRE CONFLEX are not modelled. Confirm the class, size and installation with the manufacturer or with us before you specify a product.
See also the Fire Door Selector or all engineering tools.
Frequently asked questions
Which fire curtain models are in the demo?
BACHFIRE E 120 and TRIAFIRE E 120 (integrity only, no irrigation), MEGAFIRE EI60 and MEGAFIRE EI120 (insulating, no irrigation) and SUPERFIRE EI 180 and SUPERFIRE EI 120 (insulating, with irrigation).
What happens when the mains power is lost?
The battery holds the curtain retracted. A fire alarm still deploys it, by gravity at a controlled speed.
Why does smoke get under the smoke barrier?
The smoke layer gets deeper with time. When it becomes deeper than the barrier drop, smoke spills underneath it. Try a longer drop, or remove the barrier, to compare.
Is the demo an exact simulation?
No. It shows the sequence of events for explanation. Smoke movement is a simple particle model, and colours and proportions are illustrative.