Home /Engineering Tools / Aircraft Hangar Fire Extinguishing

Aircraft Hangar Fire Protection and Fire Extinguishing Systems

An aircraft hangar combines a large fuel load, a high roof, a big open volume and very valuable aircraft. A fuel spill fire under a wing or engine spreads fast and heats the roof structure quickly. This page explains how aircraft hangar fire protection and fire extinguishing systems work. The interactive 3D demo below shows how a foam suppression system responds in each hangar group (I to IV); change the parameters to see the result.

Open full screen →

The demo is for information only; contact us for project design.

Why hangars need dedicated fire protection

Water alone does not put out a burning fuel pool, because the fuel floats and keeps burning. Hangar systems therefore combine water with foam concentrate to form a blanket that cuts off vapour and oxygen. With high ceilings, fast detection and controlled smoke and heat release matter as much as the extinguishing agent itself.

Hangar groups under NFPA 409

NFPA 409 sorts hangars into four groups. The table gives the commonly quoted criteria and typical protection; the edition in force, the construction type and the hazards on site decide the actual requirement.

GroupTypical criteriaTypical protection
Group IAircraft access door higher than 8.5 m (28 ft), or a single fire area larger than 3,716 m² (40,000 ft²)Foam-water deluge, or overhead sprinklers combined with low-level high-expansion foam, plus flame detection
Group IIDoor height up to 8.5 m and a fire area between 1,115 m² (12,000 ft²) and 3,716 m²Closed-head foam-water sprinklers, foam-water deluge or high-expansion foam
Group IIIDoor height up to 8.5 m and a fire area up to 1,115 m²Automatic water sprinklers, with foam where the hazards call for it
Group IVMembrane-covered rigid steel frame structure, defined by structure type rather than sizeVaries with size and use

Extinguishing systems used in aircraft hangars

Foam concentrate type (including fluorine-free options), proportioning equipment, pumps and water storage must follow current regulations, approvals and the manufacturer data for the chosen system.

Detection and alarm

Optical flame detectors (infrared or multi-spectrum) are normally used under high roofs because they see the fire directly instead of waiting for heat or smoke to rise. Their signal starts the alarm, opens deluge zones and can aim remote monitors at the fire. The demo shows the infrared flame detector view of the hangar floor.

Smoke and heat control

Natural smoke and heat exhaust ventilators (NSHEV) in the roof release hot gases, while the hangar doors can open as the air inlet. The demo shows the roof vents and doors opening, and the smoke layer depth against the clear height. See our smoke vent configurator and smoke and heat extraction systems.

Standards and codes

Related tools and services

Frequently asked questions

What is NFPA 409 and which hangars does it cover?

NFPA 409 is the Standard on Aircraft Hangars. It sorts hangars into Groups I to IV by aircraft access door height, fire area and construction type (membrane-covered steel frames form Group IV) and sets the fire protection each group needs. The edition in force, local regulations and the authority having jurisdiction decide the actual requirement.

Why does water alone not extinguish a hangar fuel fire?

A burning fuel pool floats on water, so water mainly cools and controls the fire. Foam forms a blanket that cuts off vapour and oxygen. That is why hangar systems combine water with foam concentrate.

Why are flame detectors used instead of smoke or heat detectors?

Hangar ceilings are high and the volume is large, so smoke and heat take time to reach ceiling detectors. Optical flame detectors see the fire directly and react within seconds, which starts the deluge or foam system early.

Is the 3D demo a design tool?

No. The demo is for information and training. A real hangar system needs project-specific design: aircraft types, fuel load, hangar dimensions, water supply, foam concentrate, detection layout, drainage and local approvals.

Can Tekno Yangın help with my hangar?

Yes. Send us the hangar dimensions, the aircraft you service and your location, and our engineers will come back to you.

Contact Us