A fire alarm system detects a fire early and warns the people in the building. The main choice is between a conventional system, which tells you which zone has an alarm, and an addressable system, which tells you which device.
The short answer
- Conventional: detectors are wired in zones. The panel shows the zone in alarm, not the exact detector. Lower cost, suited to small buildings.
- Addressable: every detector, call point and module has its own address on a loop. The panel shows the exact device, its status and faults. Suited to medium and large buildings.
How they differ
| Conventional | Addressable | |
|---|---|---|
| Location of alarm | Zone | Exact device |
| Wiring | One circuit per zone | Loop with many devices |
| Fault finding | Search the zone | Panel names the device |
| Monitoring | Limited | Device status, contamination, faults |
| Changes later | New zone wiring | Re-program, add to the loop |
| Typical building | Small shops, offices, small residential | Hotels, hospitals, malls, factories, towers |
| Equipment cost | Lower | Higher |
| Cable and labour on large sites | Higher | Lower |
On small sites conventional is cheaper. As the building grows, the saving in cable, faster fault finding and easier changes usually favour addressable.
What a system includes
Control panel, smoke, heat and multi-sensor detectors, manual call points, sounders and beacons, interface modules to other systems (door holders, ventilation, lifts, gas or sprinkler release) and power supply with battery backup. Product standards are in the EN 54 series, and installation is covered by national rules and by the project specification.
Detector choice
- Smoke detectors: offices, hotels, corridors.
- Heat detectors: kitchens, boiler rooms, places with steam or dust.
- Beam and aspirating detection: atria, warehouses, data rooms with very early warning needs.
- Linear heat detection: tunnels, conveyors, cable trays.
- Flame detectors: fuel handling and industrial hazards.
The wrong detector type is a common cause of false alarms, so match it to the space.
What drives the cost
- Number of detection points and the size of the building.
- Addressable or conventional, and the number of loops.
- Detector types: specialist detection costs more.
- Cabling: fire-rated cable, route and building access.
- Integration with other systems, sound systems and a central monitoring station.
- Commissioning, documentation and handover.
- Maintenance after handover.
An accurate price needs a design from the plans. A per-detector figure without a design only compares equipment.
Maintenance
Detectors need periodic testing and cleaning, panels need checks and batteries need replacing. Plan this from the start. See our ITM service and fire detection and alarm systems.
Sources
- EN 54 series, Fire detection and fire alarm systems
- Regulation on Fire Protection of Buildings (BYKHY), mevzuat.gov.tr